A voltammetric sensor based on NiO/CNTs ionic liquid carbon paste electrode for determination of morphine in the presence of diclofenac

A voltammetric sensor based on NiO/CNTs ionic liquid carbon paste electrode for determination of morphine in the presence of diclofenac

 
 
 

Highlights

 

Electrochemical behavior of morphine study using modified carbon paste electrode

The sensor resolved the overlap of morphine and diclofenac

This sensor is also used for the determination of morphine in real samples.

 


Abstract

A novel ionic liquid modified NiO/CNTs carbon paste electrode (IL/NiO/CNTCPE) had been fabricated by using hydrophilic ionic liquid 1-methyl-3-butylimidazolium chloride [MBIDZ]Cl as a binder. The cyclic voltammogram showed an irreversible oxidation peak at 0.61 V (vs. Ag/AgClsat), which corresponded to the oxidation of morphine. Compared to common carbon paste electrode, the electrochemical response was greatly improved for morphine electrooxidation. This modified electrode exhibited a potent and persistent electron mediating behavior followed by well separated oxidation peaks of morphine and diclofenac. Detection limit of morphine was found to be 0.01 μM using square wave voltammetry (SWV) method. The proposed sensor was successfully applied for the determination of morphine in human urine and pharmaceutical samples.

 

 

Journal Papers
Month/Season: 
February
Year: 
2014

تحت نظارت وف ایرانی

A voltammetric sensor based on NiO/CNTs ionic liquid carbon paste electrode for determination of morphine in the presence of diclofenac | Prof. Ali A. Ensafi