Silver (I)-selective coated-wire electrode based on an octahydroxycalix [4] arene derivative

Authors: Mohammad MAZLOUM ARDAKANI, Ali Asghar ENSAFI, Mohammad SALAVATI NIASARI, Hossain MIRHOSEINI
Publication date: 2003
Journal name: Analytical sciences
Volume: 19
Pages: 1187-1190
Publisher: 社団法人日本分析化学会
 
The performance of octahydroxycalix [4] arene derivative used as a neutral carrier for silver
polymeric membrane electrode was studied. The sensor gave a good Nernstian response of
58±1 mV per decade for silver ion in the activity range 3.3× 10-6 to 3.3× 10-2 M Ag+. The
limit of detection reached 2.1× 10-6 M Ag+ and exhibited high selectivity for silver ion
against the alkali, alkaline earth and transition metal ions. The sensor can be used in wide
pH range from 1.5 to 6.5. The response time of the sensor is less than 20 s. The ...

 